Trusted RO & Water Purifier Service 9211627332
RO water purifier repair and servicing

250 LPH RO Plant, Commercial RO Plant 250 LPH

Commercial reverse osmosis water purification with a multi-stage filtration system.

250 LPH RO Plant

Image for presentation only. Actual product will be different from the product shown.

250 LPH RO Plant suitable for home and office use. In whole day approx give 2500 liter to 3000 liter pure water. Store this water for your home or staff.
Use raw water 300 TDS to 2000 TDS in Commercial ro plant 250 lph. That's output in TDS approximately 50 to 150 TDS. You have to store water in water cooler or water tank as suitable to you.

250 LPH Commercial RO Plant for Daily Water Needs

The 250 LPH commercial RO plant is designed for applications that need a steady supply of purified water. It can be considered for offices, workplaces, small commercial facilities and other sites where water demand, raw-water quality and storage requirements have been assessed.

The system uses multiple treatment stages, including pre-filtration, chemical dosing, micron filtration and reverse osmosis. These stages help prepare feed water for the RO membrane and support the system's water-treatment process. Actual output and treated-water quality depend on feed-water conditions, system setup and maintenance.

Multi-stage treatmentPre-filtration and RO treatment stages
250 LPH rated capacityConfirm actual performance against feed-water conditions
Commercial applicationsSuitable uses depend on site requirements

Before selecting a plant, review the raw-water test report, required daily quantity, available installation space, drainage and storage arrangements. Our team can help discuss the application and the configuration needed for your site.

Need help choosing a 250 LPH RO Plant? Call Gaurav Water Solution to discuss your water-treatment requirements.
Call Now: 9211627332

250 Liters Per Hour RO Plant

Description

Technical Details:

ASSUMPIONS

DescriptionSpecification
FEED WATER TDS 1000ppm
Fluorides < 1 ppm
Iron < 0.1 ppm
Turbidity < 5
pH Less than 7.5 and greater than 6.5

Scheme:

Raw Water Pump → Sand Filter → Carbon Filter → Anti Scalent Dosing System → Micro Filtration → High Pressure Pump → Membrane.
DescriptionSpecification
FEED WATER 1000PPM
FEED WATER TDS 1000PPM
PRODUCT WATER 250LPH
RECOVERY 60%
SALT REJECTION 95%

In case of high Turbidity customer needs to provide a settlement tank and Alum dosing system is to be incorporated. The cost of the same has not been considered with in the scheme.

TECHNICAL SPECIFICATION

FEED Water Pump

The system would require an Inlet Pressure of 1.5 Kg/cm2 minimum for smooth operation. To provide the same the Raw Water Pump is being incorporated in the system.

Description

DescriptionSpecification
Make CG
Power 1 Hp
Volts 230 volts
Phase Single
Type Mono Block

PRESSURE SAND FILTER

The system is required to be feed with "0" turbidity water. The Pressure Sand Filter is incorporated in the system to ensure the same. The Pressure Sand Filter offers a filtration up to 30 microns.

The Filter consists of a Non Corrosive Vessel that can withstand pressure up to 6.5 Kgs/cm2, Multi Graded Sand Filtration Media for filtration, Internal Distribution System to distribute the water evenly inside the vessel for proper filtration, Multi Port Value (MPV) for easier operation along with Back Wash and Rinse facilities, a stand to hold the MPV in position and Pressure Gauges to know the position of the sand filter.

The filter is designed for 14m/sec internal flow for proper filtration.

Description

DescriptionSpecification
Vessel FRP
Size 8"44"
Volume 34 Lts
Multi Port Value Filter 25 Nb Top Mounted
Media Silica Sand Multi Grade
Min Operating Pressure 1.5kg/Cm2
Max Operating Pressure 4.5kg/Cm2
Avg Operating Pressure 2-3kg/Cm2

ACTIVE CARBON FILTER (ACF)

This system is required to be feed with NIL Chlorine water. The Activated Carbon Filter is incorporated in the system to ensure the same. It also ensures that the water is color less, odor less and contains no dissolved gases.

The Filter consists of a Non Corrosive Vessel that can withstand pressure up to 6.5Kgs/cm2, Multi Graded Sand and Activated Carbon Filtration Media for filtration, Internal Distribution System to distribute the water evenly inside the vessel for proper filtration, Multi Port Value (MPV) for easier operation along with Back Wash and Rinse facilities, a stand to hold the MPV in position and Pressure Gauges to know the position of the Activated Carbon filter.

The filter is designed for 14 m/sec internal flow for proper filtration.

Description

DescriptionSpecification
Vessel FRP
Size 8"44"
Volume 34 Lts
Multi Port Value 25 Nb Top Mounted Filters
Media Activated Carbon
Min Operating Pressure 1.5kg/Cm2
Max Operating Pressure 4.5kg/Cm2
Avg Operating Pressure 2-3kg/Cm2

ANTI SCALENT DOSING SYSTEM

The ANTI SCALENT DOSING SYSTEM gives the system an extra protection towards any kind of scale formation over the membranes. Chemicals are chosen depending on the water analysis report of the raw water. These chemicals are dosed in the water inflow drop by drop. The chemicals agitate the dissolved particles in the water so as not to allow them to settle down on the membrane surface.

Description

DescriptionSpecification
Make Altawel/E-Dose
Type Diaphragm Type Metering Pump
MOC of Diaphragm PP
Capacity 6 LPH
Drum (100 Ltr) Plastic
Anti Scalent Chemical 1 Litre

MICRON FILTER

Due to the induction of the dosing chemical some of the particles may coagulate in the water. This coagulated particle cannot be allowed to enter the membrane. The Micron Filter ensures that all such particles above the size of 5 micron are being filtered out of the water so as to enhance the system life. It also ensures that even all un dissolved particles above the size of 5 Micron are being filtered out.

Description

DescriptionSpecification
No. Offered One
Jumbo Housing PP
Specs One
Filters Nos. Offered One
Micron Rating 5 Micron

HIGH PRESSURE PUMP

In the system, the membrane filtration takes place at high pressure only in the range of 8-14 KG/CM2. To provide such high pressure the Pressure Booster Pump is being induced in the system to boost the pressure to the required level for the proper filtration process.

Description

DescriptionSpecification
Make PURE & CURE
Power Single Phase
Type Horizontal Multi Stage
Pressure Rating 1.5 M3 At 140m Head
Max Pressure 17 Kgs/Cm2
Normal Operating Pressures 8-14 Kgs/Cm2

MEMBRANE HOUSING

The membrane housing provides the shell for the membranes to allow the highly pressurized water to pass through the membrane.

Description

DescriptionSpecification
MOC FRP
No. Offered One
Specs 4:40 (Single Element)
Max Pressure 21 Kgs/ Cm2
Operating Pressure 9-14 Kgs/ Cm2

MEMBRANE

The system consists of Thin Film Composite Membrane made out of Poly Urethane acetate that provides a filtration level up to 0.0001 micron. These operate at a pressure between 9-14 kgs/cm2 this result in a dissolved salt rejection of up to 95%. The membrane separates the water into two streams. One is the premed or the product water and the other is the rejection.

Description

DescriptionSpecification
Specs 4040
No. Offered One
Operating Pressure 9-14 Kgs/ Cm2

ACCESSORIES

ELECTRICAL CONTROL PANEL

DescriptionSpecification
MOC Plastic
Power Single Phase
Condutivity Meter Inbuilt
LPS Adjuster Inbuilt
HPS Adjuster Inbuilt

WET PANEL

DescriptionSpecification
MOC Plastic
Flow Meters Two
Pressure Gauges Two
LPS One
HPS One

SKID

DescriptionSpecification
MOC Stainless steel

PIPING

DescriptionSpecification
Raw Water Pump To Micron Filter UPVC
Micron Filter To Flow Meters UPVC
Product Line UPVC (As Per FDA &NSF)
Reject Line UPVC
Price: 153,400
Availability: In Stock
Free Shipping.
Call Now WhatsApp Book Now