Trusted RO & Water Purifier Service 9211627332
RO water purifier repair and servicing

1000 LPH RO Plant, Commercial RO System 1000 LPH

Commercial reverse osmosis water purification system designed for applications requiring approximately 1000 litres per hour of treated water under specified operating conditions.

1000 LPH RO Plant

Image for presentation only. Actual product may be different from the product shown.

1000 Liter RO Plant

Technical Details

Assumptions
FEED WATER TDS 4500 ppm
Fluorides < 1 ppm
Iron < 0.1 ppm
Turbidity < 5
pH < 7.5 & > 6.5
Scheme
  Raw Water Pump → Sand Filter → Carbon Filter → Anti Scalent Dosing System → Micro Filtration → High Pressure Pump → Membrane
FEED WATER 4500 LPH
FEED WATER TDS 2500 PPM
PRODUCT WATER 1000 LPH
RECOVERY 55% to 75%
SALT REJECTION 95%

In case of high turbidity, the customer needs to provide a settlement tank and Alum dosing system is to be incorporated. The cost of the same has not been considered within the scheme.

Technical Specification

Feed Water Pump

The system would require an inlet pressure of 1.5 Kg/cm² minimum for smooth operation. To provide the same, the Raw Water Pump is incorporated in the system.

Make CG
Power 1.5 HP
Volts 230 Volts
Phase Single
Type Mono Block
Pressure Sand Filter

The system is required to be fed with "0" turbidity water. The Pressure Sand Filter is incorporated in the system to ensure the same. The Pressure Sand Filter offers filtration up to 30 microns.

The filter consists of a non-corrosive vessel that can withstand pressure up to 6.5 Kgs/cm², multi-graded sand filtration media, internal distribution system, Multi Port Valve (MPV), backwash and rinse facilities, stand and pressure gauges.

The filter is designed for proper internal flow for effective filtration.

Vessel Paintair
Size 13" × 54"
Volume 105 Lts
Media Silica Sand Multi Grade
Min Operating Pressure 1.5 kg/cm²
Max Operating Pressure 4.5 kg/cm²
Avg Operating Pressure 2–3 kg/cm²
Active Carbon Filter (ACF)

This system is required to be fed with NIL chlorine water. The Activated Carbon Filter is incorporated in the system to help ensure this condition. It also helps reduce colour, odour and dissolved gases.

The filter consists of a non-corrosive vessel, multi-graded sand and activated carbon filtration media, internal distribution system, Multi Port Valve (MPV), backwash and rinse facilities, stand and pressure gauges.

The filter is designed for proper internal flow for effective filtration.

Vessel Painter
Size 13" × 54"
Volume 105 Lts
Multi Port Valve 25 NB Top Mounted Filters
Media Activated Carbon
Min Operating Pressure 1.5 kg/cm²
Max Operating Pressure 4.5 kg/cm²
Avg Operating Pressure 2–3 kg/cm²
Anti Scalent Dosing System

The Anti Scalent Dosing System gives the system additional protection against scale formation over the membranes. Chemicals are selected depending on the water analysis report.

Make E-Dose
Type Diaphragm Type Metering Pump
MOC of Diaphragm PP
Capacity 6 LPH
Drum (100 Ltr) Plastic
Anti Scalent Chemical 1 Litre
Micron Filter

Due to the induction of the dosing chemical, some particles may coagulate in the water. The Micron Filter helps remove particles above the specified micron rating before the membrane stage.

No. Offered Two
Jumbo Housing PP
Specs Single Elements
Filters Nos. Offered Two
Micron Rating 5 Micron
High Pressure Pump

In the system, membrane filtration takes place at high pressure in the range of 8–14 KG/cm². The Pressure Booster Pump provides the pressure required for the filtration process.

Make Kirloskar, LUBY, CRI
Power Single Phase
Type Vertical Multi Stage
Pressure Rating 1.5 M3 At 140m Head
Max Pressure 17 Kgs/cm²
Normal Operating Pressures 8–14 Kgs/cm²
Membrane Housing

The membrane housing provides the shell for the membranes and allows highly pressurized water to pass through the membrane.

MOC FRP
No. Offered Two
Specs 440 (Two Element)
Max Pressure 21 Kgs/cm²
Operating Pressure 9–14 Kgs/cm²
Membrane

The system consists of Thin Film Composite Membranes. These operate at pressure between 9–14 Kgs/cm² and separate the water into product and reject streams.

Make Hydronautics / CSM / Vontron
Specs 4040
No. Offered Four
Operating Pressure 9–14 Kgs/cm²

Accessories

Electrical Control Panel
MOC Plastic
Power Single Phase
Conductivity Meter Inbuilt
LPS Adjuster Inbuilt
HPS Adjuster Inbuilt
Wet Panel
MOC SS
Flow Meters Two
Pressure Gauges Two
LPS One
HPS One
Skid
MOC Stainless Steel
Piping
Raw Water Pump To Micron Filter UPVC
Micron Filter To Flow Meters UPVC
Product Line UPVC (As Per FDA & NSF)
Reject Line UPVC

About 1000 LPH RO Plant

Commercial Water Purification Solution

The 1000 LPH Commercial RO Plant is designed for businesses and institutions that require a continuous supply of treated water. The system combines pre-treatment, filtration, high-pressure pumping and membrane filtration stages.

1000 LPH Capacity

Designed for a product-water output of approximately 1000 litres per hour under specified operating conditions.

Multi-Stage Filtration

Includes pre-treatment, micron filtration and membrane-based reverse osmosis stages.

Commercial Applications

Suitable for commercial and institutional water treatment requirements.

Requirement-Based Setup

Final equipment selection can depend on feed-water quality and site requirements.

Before Choosing Your RO Plant

  • Check raw water TDS and overall water quality.
  • Confirm the required treated-water capacity for your application.
  • Discuss installation, space and maintenance requirements.
  • Select the final configuration according to the site conditions.
NEED HELP? Discuss Your Commercial RO Plant Requirements 92116 27332
Call Now
Product Price
295000
In Stock

  Free Shipping

Book Now