Commercial reverse osmosis water purification system designed for applications requiring approximately 1000 litres per hour of treated water under specified operating conditions.
Image for presentation only. Actual product may be different from the product shown.
| FEED WATER TDS | 4500 ppm |
| Fluorides | < 1 ppm |
| Iron | < 0.1 ppm |
| Turbidity | < 5 |
| pH | < 7.5 & > 6.5 |
| FEED WATER | 4500 LPH |
| FEED WATER TDS | 2500 PPM |
| PRODUCT WATER | 1000 LPH |
| RECOVERY | 55% to 75% |
| SALT REJECTION | 95% |
In case of high turbidity, the customer needs to provide a settlement tank and Alum dosing system is to be incorporated. The cost of the same has not been considered within the scheme.
The system would require an inlet pressure of 1.5 Kg/cm² minimum for smooth operation. To provide the same, the Raw Water Pump is incorporated in the system.
| Make | CG |
| Power | 1.5 HP |
| Volts | 230 Volts |
| Phase | Single |
| Type | Mono Block |
The system is required to be fed with "0" turbidity water. The Pressure Sand Filter is incorporated in the system to ensure the same. The Pressure Sand Filter offers filtration up to 30 microns.
The filter consists of a non-corrosive vessel that can withstand pressure up to 6.5 Kgs/cm², multi-graded sand filtration media, internal distribution system, Multi Port Valve (MPV), backwash and rinse facilities, stand and pressure gauges.
The filter is designed for proper internal flow for effective filtration.
| Vessel | Paintair |
| Size | 13" × 54" |
| Volume | 105 Lts |
| Media | Silica Sand Multi Grade |
| Min Operating Pressure | 1.5 kg/cm² |
| Max Operating Pressure | 4.5 kg/cm² |
| Avg Operating Pressure | 2–3 kg/cm² |
This system is required to be fed with NIL chlorine water. The Activated Carbon Filter is incorporated in the system to help ensure this condition. It also helps reduce colour, odour and dissolved gases.
The filter consists of a non-corrosive vessel, multi-graded sand and activated carbon filtration media, internal distribution system, Multi Port Valve (MPV), backwash and rinse facilities, stand and pressure gauges.
The filter is designed for proper internal flow for effective filtration.
| Vessel | Painter |
| Size | 13" × 54" |
| Volume | 105 Lts |
| Multi Port Valve | 25 NB Top Mounted Filters |
| Media | Activated Carbon |
| Min Operating Pressure | 1.5 kg/cm² |
| Max Operating Pressure | 4.5 kg/cm² |
| Avg Operating Pressure | 2–3 kg/cm² |
The Anti Scalent Dosing System gives the system additional protection against scale formation over the membranes. Chemicals are selected depending on the water analysis report.
| Make | E-Dose |
| Type | Diaphragm Type Metering Pump |
| MOC of Diaphragm | PP |
| Capacity | 6 LPH |
| Drum (100 Ltr) | Plastic |
| Anti Scalent Chemical | 1 Litre |
Due to the induction of the dosing chemical, some particles may coagulate in the water. The Micron Filter helps remove particles above the specified micron rating before the membrane stage.
| No. Offered | Two |
| Jumbo Housing | PP |
| Specs | Single Elements |
| Filters Nos. Offered | Two |
| Micron Rating | 5 Micron |
In the system, membrane filtration takes place at high pressure in the range of 8–14 KG/cm². The Pressure Booster Pump provides the pressure required for the filtration process.
| Make | Kirloskar, LUBY, CRI |
| Power | Single Phase |
| Type | Vertical Multi Stage |
| Pressure Rating | 1.5 M3 At 140m Head |
| Max Pressure | 17 Kgs/cm² |
| Normal Operating Pressures | 8–14 Kgs/cm² |
The membrane housing provides the shell for the membranes and allows highly pressurized water to pass through the membrane.
| MOC | FRP |
| No. Offered | Two |
| Specs | 440 (Two Element) |
| Max Pressure | 21 Kgs/cm² |
| Operating Pressure | 9–14 Kgs/cm² |
The system consists of Thin Film Composite Membranes. These operate at pressure between 9–14 Kgs/cm² and separate the water into product and reject streams.
| Make | Hydronautics / CSM / Vontron |
| Specs | 4040 |
| No. Offered | Four |
| Operating Pressure | 9–14 Kgs/cm² |
| MOC | Plastic |
| Power | Single Phase |
| Conductivity Meter | Inbuilt |
| LPS Adjuster | Inbuilt |
| HPS Adjuster | Inbuilt |
| MOC | SS |
| Flow Meters | Two |
| Pressure Gauges | Two |
| LPS | One |
| HPS | One |
| MOC | Stainless Steel |
| Raw Water Pump To Micron Filter | UPVC |
| Micron Filter To Flow Meters | UPVC |
| Product Line | UPVC (As Per FDA & NSF) |
| Reject Line | UPVC |
Commercial Water Purification Solution
The 1000 LPH Commercial RO Plant is designed for businesses and institutions that require a continuous supply of treated water. The system combines pre-treatment, filtration, high-pressure pumping and membrane filtration stages.
Designed for a product-water output of approximately 1000 litres per hour under specified operating conditions.
Includes pre-treatment, micron filtration and membrane-based reverse osmosis stages.
Suitable for commercial and institutional water treatment requirements.
Final equipment selection can depend on feed-water quality and site requirements.
Free Shipping