Explore the technical specifications of this 100 LPH commercial reverse osmosis plant, including the feed water pump, micron filter, high-pressure pump, membrane housing, electrical panel, and stainless steel skid.

Product Price
₹58,000
In Stock
100 LPH commercial RO plant

Image for presentation only. Actual product may differ from the product shown.

100 LPH Capacity Rated product water output
RO Filtration Multistage purification process
Commercial System For commercial applications
Stainless Steel Skid As specified for the system
Product Information

100 LPH Commercial RO Plant

Review the listed feed water assumptions and process specifications before selecting the plant for your water treatment requirements.

Plant Overview

This commercial reverse osmosis system is specified for a nominal product water output of 100 litres per hour.

The listed configuration includes a feed water pump, micron filtration, a high-pressure pump, membrane housing, RO membrane, electrical control panel, wet panel, skid, and associated piping.

Actual output and recovery depend on feed water quality, temperature, pressure, membrane condition, and the final system configuration.

Feed Water Assumptions

Parameter Specification
Feed Water TDS 4500 ppm
Fluorides Less than 1 ppm
Iron Less than 0.1 ppm
Turbidity Less than 5
pH 6.5 to 7.5
Filtration Process

RO Plant Working Scheme

The listed process sequence illustrates the major filtration stages of the system.

Sand Filter
Carbon Filter
Micro Filtration
High-Pressure Pump
RO Membrane
Feed water treatment note
The original specification notes that high turbidity may require a settling tank and an alum dosing system. Their cost is not included in the listed scheme. Confirm the required pretreatment after analysing the actual feed water.

Process Specifications

Parameter Specification
Feed Water 4500 LPH
Feed Water TDS 2500 ppm
Product Water 100 LPH
Recovery 55% to 75%
Salt Rejection 95%
Technical Details

Pumps and Filtration Components

Specifications for the feed water pump, micron filter, and high-pressure pump.

Feed Water Pump

The original specification requires a minimum inlet pressure of 1.5 kg/cm² for smooth operation and lists a raw water pump for this purpose.
Parameter Specification
Make CG
Power 0.5 HP
Voltage 230 volts
Phase Single phase
Type Monoblock

Micron Filter

The micron filter is intended to remove suspended and undissolved particles above the specified filtration rating before water enters the membrane stage.
Parameter Specification
Number Offered Two
Jumbo Housing PP
Specifications Single elements
Number of Filter Elements Two
Micron Rating 5 micron

High-Pressure Pump

The high-pressure pump supplies the pressure required for the membrane filtration process. The final operating pressure must be verified against the selected membrane and system design.
Parameter Specification
Make Kirloskar, LUBY, CRI
Power Supply Single phase
Type Vertical multistage
Pressure Rating 0.5 m³ at 140 m head
Maximum Pressure 17 kg/cm²
Normal Operating Pressure 8–14 kg/cm²

Membrane Housing

The membrane housing contains the membrane element and provides an enclosure suitable for the specified operating pressure.
Parameter Specification
Material of Construction FRP
Number Offered One
Specifications One element
Maximum Pressure 21 kg/cm²
Operating Pressure 9–14 kg/cm²
RO Technology

Reverse Osmosis Membrane

The membrane separates feed water into product water and reject water under pressure.

Membrane Details

Parameter Specification
Make Hydranautics / CSM / Vontron
Specifications 100 LPH
Number Offered One
Operating Pressure 5–10 kg/cm²

Membrane Description

The original product description specifies a thin-film composite membrane and lists Hydranautics, CSM, and Vontron as possible makes.

Reverse osmosis uses a pressure-driven membrane process to separate dissolved salts and other constituents from water. Product quality and salt rejection depend on the membrane model and operating conditions.

Confirm the final membrane brand, model, pressure requirements, and compatibility with the feed water before purchase.

Electrical Accessories

Control Panel and Wet Panel

Review the listed electrical controls, monitoring equipment, and panel construction.

Electrical Control Panel

Parameter Specification
Material of Construction Plastic
Power Supply Single phase
Conductivity Meter Inbuilt
LPS Adjuster Inbuilt
HPS Adjuster Inbuilt

Wet Panel

Parameter Specification
Material of Construction Stainless steel
Flow Meters Two
Pressure Gauges One
LPS One
HPS One
Construction Details

Skid and Piping Specifications

Construction materials and piping details listed for the commercial RO plant.

Plant Skid

Parameter Specification
Material of Construction Stainless steel

Piping Details

Parameter Specification
Raw Water Pump to Micron Filter UPVC
Micron Filter to Flow Meters UPVC
Product Line UPVC (as specified: FDA/NSF)
Reject Line UPVC
Commercial RO System

Interested in the 100 LPH RO Plant?

Review the specifications and contact Gaurav Water Solution for product availability, final configuration, installation requirements, and quotation.

Listed price: ₹58,000
Confirm the final price and included equipment before placing your order.